[Home][2018 Index] Re: [TCML] Bleeder resistor for Maxwell cap [Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TCML] Bleeder resistor for Maxwell cap



Steve,

You can put a NE-2 neon lamp across the meter, and/or 6 or 7 forward biased 1N400x class silicon diodes in series.  Neither will conduct significantly unless the 10K resistor goes open.

Dave


On 2/8/2018 8:49 AM, steve date wrote:
......And, if the 10k is bad you will get to see what happens to a voltmeter when offered 15kv.  Please be safe.

steve-seattle



On 2/8/2018 12:22 AM, Albert via Tesla wrote:
I would add a 10k resistor to the end of the 79M chain and put the chain across the HV.

Then  use a standard AC voltmeter to check if there are low volts across the 10k,

using safety proceedures, of course.

With HV at, say 15kv, the volts across the 10k will be approx 2v

thus indicating that the chain is intact.

_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxxxxxx
https://www.pupman.com/mailman/listinfo/tesla