[Home][2018 Index]
Then use a standard AC voltmeter to check if there are low volts across the 10k,
using safety proceedures, of course. With HV at, say 15kv, the volts across the 10k will be approx 2v thus indicating that the chain is intact. On 08/02/2018 03:30, Gary Lau wrote:
78 Meg is higher than most multimeters can read so you need to be creative in verifying that sub-sections of the series chain are intact, thereby implying that the entire chain is wired intact. <http://www.avg.com/email-signature?utm_medium=email&utm_source=link&utm_campaign=sig-email&utm_content=webmail> Virus-free. www.avg.com <http://www.avg.com/email-signature?utm_medium=email&utm_source=link&utm_campaign=sig-email&utm_content=webmail> <#DAB4FAD8-2DD7-40BB-A1B8-4E2AA1F9FDF2> On Wed, Feb 7, 2018 at 1:40 PM, dennis otmaskin <dotmaskin@xxxxxxxxx> wrote:I would appreciate some guidance on the proper bleeder resistor for a 35kV .003uF Maxwell pulse capacitor (#367667) or where I can go to find this info. Thank you! Dennis, Hopkinton MA _______________________________________________ Tesla mailing list Tesla@xxxxxxxxxxxxxxxxxx https://www.pupman.com/mailman/listinfo/tesla_______________________________________________ Tesla mailing list Tesla@xxxxxxxxxxxxxxxxxx https://www.pupman.com/mailman/listinfo/tesla
_______________________________________________ Tesla mailing list Tesla@xxxxxxxxxxxxxxxxxx https://www.pupman.com/mailman/listinfo/tesla