Bart,
Thanks much for a starting range. I have my feeler gauge (50mm) in hand and
will document the resulting discharge voltage @ 800ft.
Jim Mora
-----Original Message-----
From: tesla-bounces@xxxxxxxxxx [mailto:tesla-bounces@xxxxxxxxxx] On Behalf
Of bartb
Sent: Friday, April 10, 2009 5:50 PM
To: Tesla Coil Mailing List
Subject: Re: [TCML] 5kv plane gap size
Hi Jim,
I'm not sure how elevation will vary this value, but breakdown should be
right at 50mils (pretty narrow). But depending on the surface of the
dowels, elevation, pressure, etc.. the gap setting may need to be
slightly larger a few mils to achieve a 5kv breakdown.
Bart
Jim Mora wrote:
Hi List,
Does anyone know the DC gap breakdown size for 5KV via large, flat dowels
at
~800ft-1000ft elevation is? Most of what I find on the Inet are for higher
voltages.
I may have to trigger this, but; I am trying to keep it simple.
Thanks much,
Jim Mora
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla