[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[TCML] BIGPIG secondary dies...but may be resurected
Hey All...
Back again... anyway I went out back into the shop and tried to remove
some of the damaged coating around the burn site. Luckily the tube wasnt
damaged, but there was about a 3" strip going upwards of the original
arc point that got scorched ( coating only). Since the coating had
hardened, removing it was all a matter of tapping the coating with a
rubber mallet and then using an air gun at 120 psi to remove rather
large chunks of coating from the wire. On average I would say the pieces
were about half the size of a playing card and in some cases the pieces
were 2X the size of a card. Ended up removing 90% of the coating in
about an hour. ( secondary is 12.5" dia X 55" wound length. In general,
the wire looks to be in great condition ( except for about 5 turns where
the insulation was damaged). Guess I'll just do a splice job there.
Maybe someone out here knows the answers to my next questions....
What would be the effect of winding a coil with say 18 ga for 3/4 length
of tube and then finishing it off with 22 or 24 ga on the last 1/4
length?? Since the current is less towards the top of the coil, the
thinner wire "should" be able to handle it. And how would I calculate L
for the secondary if this is to be wound in this manner? ( calc each as
individual L's and then add inductance for a total??)
Scot D
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla