[Prev][Next][Index][Thread]
Re: Ballasting ..... Again
> Original Poster: Mark Finnis <mefinnis-at-medicine.adelaide.edu.au>
> My 5 kVA transformer is nearing completion. Wound up using 0.71mm wire for
> the new secondary. Needed 19 layers/winding to get 60:1 and 14.4 kV, but
> due to thickness of insulation etc the window will only allow 18 layers
> .... still, 13.6 kV will do just fine ;-)
>
> The point of the post is to discuss ballasting this monster. I have a 15A
> variac, which will limit me to 3.6 kV theoretically (though I could
> probably squeeze a little more for short runs). I have a quantity of
> left-over wire from the primary (it had windings out to 440V - since
> removed) which I could use for an inductor with an appropriate core. This
> wire is rectangular and about 3.5 x 2mm .... quite heavy !
Gee, if you're going through all the trouble of
winding your own (50Hz!) transformer, why don't
you include a magnetic shunt on the transformer
core itself to provide the ballasting function?
--
-GL
www.lod-dot-org