[Home][2020 Index] Re: [TCML] plastic pipe for secondaries [Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TCML] plastic pipe for secondaries



Jim,

I've used both the SDR pipe and normal PVC up to sch 120.  I then turned to
using PVC Heat Duct pipe.  It has thin walls and comes in diameters up to
at least 24" which makes larger secondaries much lighter.  Originally, I
had some concerns about it being gray (possibly due to carbon in it),
however, although I didn't specifically measure it, I did not see any
noticeable difference in performance.

Here's a link to one company that sells it:

https://www.indelco.com/c-2352-pvc-gray-duct-pipe.aspx

Best regards,

David L. McKinnon


On Thu, Jan 30, 2020 at 11:01 AM jimlux <jimlux@xxxxxxxxxxxxx> wrote:

> Does anyone have practical experience with PVC plastic pipe, comparing
> SDR (Sewer) vs D2729 (Drain) - the drain pipe is about half the wall
> thickness (0.1", 2.5 mm) and is cheaper and lighter.
>
>
> _______________________________________________
> Tesla mailing list
> Tesla@xxxxxxxxxxxxxxxxxx
> https://www.pupman.com/mailman/listinfo/tesla
>
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxxxxxx
https://www.pupman.com/mailman/listinfo/tesla