Re: [TCML] MOT stack replaced with PT, performance gone
Team
By way of example
If a 4 MOT system has a total leakage inductance of say 24Hy (i.e. 4x6Hy)
the Cp required to resonant (60Hz) with that calculates to 293nF. This is
very much in the ball-park of typical Cp's and my estimate for the leakage L
is very approximate. I believe there is lots of scope for MOT systems to
resonant with the mains supply and substantially alter the throughput by
presenting a near conjugate match to the transformers.
Rgds
Ted in NZ
-----Original Message-----
From: Scott Bogard
Sent: Saturday, July 14, 2012 4:26 AM
To: Tesla Coil Mailing List
Subject: Re: [TCML] MOT stack replaced with PT, performance gone
Hi Mark, Ted,
That is interesting, and it sort of makes sense. To say what Ted did
in simpler terms, even though the power supply (whether MOTs or a
<SNIP>