[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TCML] Allanson GFI question



The third wire will be the ground wire.  Make sure it's grounded, if it's
not you'll fry the transformer.

On Thu, Oct 30, 2008 at 17:46, Shawn Moses <loricipheran@xxxxxxxxx> wrote:

> Hi -This is my first posting to this list.  I have a 15/60 Allanson NST
> (Cat # 1560FPX120) that has GFI protection.  This afternoon, I depotted the
> front compartment and removed the GFI module.  I had downloaded some
> schematics of Allanson GFI's, but my module is not of the same
> configuration, so the diagrams don't help.  There are three wires leading
>  from the GFI module into the main compartment.  Two of them are obviously
> the primary leads - they are heavier gauge (14 AWG I'd say), and test
> positive for continuity.  However, I'm not sure what the third wire is.  It
> is white and smaller gauge than the other two.  The terminal where it
> connects to the GFI is labeled "ORG, and leads to the shutoff relay.
>  Anybody know what I should do with this wire?  I'm thinking cap it off, but
> I wasn't sure.Thanks,
>
> Shawn
>
>
>
>
> _______________________________________________
> Tesla mailing list
> Tesla@xxxxxxxxxxxxxx
> http://www.pupman.com/mailman/listinfo/tesla
>