[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TCML] Allanson GFI question



I think that the third wire might be the center tap/ground.  Try putting an ohm meter across one HV lead and the 3rd wire, then the other HV lead and the third wire, if it conducts it is probably the ground.  
At least this has been my experience with extra wires like that.  I have always connected them to the house ground via the third prong of the outlet.

Jay H
-------------- Original message -------------- 
From: Shawn Moses <loricipheran@xxxxxxxxx> 

> Hi -This is my first posting to this list. I have a 15/60 Allanson NST (Cat # 
> 1560FPX120) that has GFI protection. This afternoon, I depotted the front 
> compartment and removed the GFI module. I had downloaded some schematics of 
> Allanson GFI's, but my module is not of the same configuration, so the diagrams 
> don't help. There are three wires leading from the GFI module into the main 
> compartment. Two of them are obviously the primary leads - they are heavier 
> gauge (14 AWG I'd say), and test positive for continuity. However, I'm not sure 
> what the third wire is. It is white and smaller gauge than the other two. The 
> terminal where it connects to the GFI is labeled "ORG, and leads to the shutoff 
> relay. Anybody know what I should do with this wire? I'm thinking cap it off, 
> but I wasn't sure.Thanks, 
> 
> Shawn 
> 
> 
> 
> 
> _______________________________________________ 
> Tesla mailing list 
> Tesla@xxxxxxxxxxxxxx 
> http://www.pupman.com/mailman/listinfo/tesla 