[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: [TCML] MMC building - some questions



30 mA only :-(

-----Original Message-----
From: tesla-bounces@xxxxxxxxxx [mailto:tesla-bounces@xxxxxxxxxx] On Behalf
Of bartb
Sent: 05 October 2008 19:34
To: Tesla Coil Mailing List
Subject: Re: [TCML] MMC building - some questions

Hi Thomas,

For a 6kV NST, 16 caps may be overboard. DC did not know your 
transformer voltage and this would certainly change the MMC design. What 
is your 6kV NST current?
Bart

Thomas Ryckmans wrote:
> Sorry, I should have mentioned to all that I am using a 6000V nst. 
>
> Anyway, I'll do 2 strings of 16 caps as per DC's instructions
>
> Thanks to all - 19 days to the Cambridge UK Teslathon now!
>
> - Thomas
>   
>
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla

_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla