[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [TCML] What length for 13".
4.5:1 height/dia ratio offers good performance and reduces spark discharges
to primary.
Use a sharp point off the toroid elevated at 20 degrees for long spark
lengths.
13" dia. x 4.5 height/dia ratio = 58.5" winding length
Using 1,000 total turns (pole xmfr), then 58.5" winding length / 1,000 turns
= .0585" OD wire size = 17 AWG wire size
If it's a nst power coil, then 1,400 total turns offers good performance, so
58.5" / 1,400 turns = .042" OD wire size = 18 AWG wire size
Use double-build enamel magnet wire for good performance and best dielectric
properties.
Many happy sparks,
Dr. Resonance