[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [TCML] Large Plsma Tube
The tube has to be fully vented to the air every time. If you keep a vacuum
in the tube it may slowly suck the oil out of the vac pump and into the
tube --- a big mess. Ask me how I know.
We usually pump for 10 min and then shut off the valve going to the pump. A
second value allows us to bleed air into the tube very slowly with a
precision Hoke 10 turn valve. We always start with high vac so the rings
are visible, and then go to bright pink which is near atm pressures.
Dr. Resonance
Resonance Research Corp.
www.resonanceresearch.com
----- Original Message -----
From: "David N. Van Doren" <DNVanDoren@xxxxxxxxxxx>
To: "Tesla Coil Mailing List" <tesla@xxxxxxxxxx>
Sent: Friday, November 30, 2007 10:42 AM
Subject: Re: [TCML] Large Plsma Tube
Dr. R is that 14.4 kV 800 mA @ 60Hz? Other than to back bleed other
gases, why do you pump down the tube first ( to outgas all thats going to
outgas?) and how far?
This is starting to jell in my mind quit nicly thanks Everyone.