[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: NST and GFI protection
Original poster: "steven hyman" <steve502-at-bellsouth-dot-net>
all ready tried it the TC fires for about 5 seconds and then turns off,I am
assuming this is the GFI circuit
doing what it supposed to,
there is a small reset switch on the outside , the NST is potted with some
beige colored waxlike material
but the the inside of the reset switch sits above the potting material ,
what do you think of shorting that switch ?
Steve
----- Original Message -----
From: "Tesla list" <tesla-at-pupman-dot-com>
To: <tesla-at-pupman-dot-com>
Sent: Monday, February 23, 2004 2:36 PM
Subject: Re: NST and GFI protection
> Original poster: Terry Fritz <teslalist-at-twfpowerelectronics-dot-com>
>
> HI,
>
> Hopefully, you can just remove the cover and find all the electronics
right
> there easy to get at. Then figure out where all the wires go or short
> across the offending relay. I used to have pictures, but they seem to
have
> gotten missplaced somewhere in hot-streamer's gigs of files... But you
may
> want to wait and try it since sometimes they seem to work as is.
>
> Cheers,
>
> Terry
>
>
> At 08:34 AM 2/23/2004, you wrote:
> >hey guys
> >
> >Is any one aware of ways to disable the GFI protection on the new NST's
> >Some has given ( Yes for Free ) a 15/60 with GFI id like to use
> >
> >
> >thanks
> >Steve
>
>
>