[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: 240V arc welder ballast settings



Original poster: "BunnyKiller by way of Terry Fritz <twftesla-at-qwest-dot-net>" <bigfoo39-at-telocity-dot-com>

Tesla list wrote:

>Original poster: "J Whyte by way of Terry Fritz <twftesla-at-qwest-dot-net>"
<xoom321-at-hotmail-dot-com>
>
>(....this is slightly off topic---> but rather important)
>
>I am planning on using an arc welder for my next huge power supply. However, 
>I am curious about typical arc welder output volts on a 240V AC welder.
>
>I am curious if AC arc welder voltage output stay the same as the input 
>voltage/ and amperage is the only thing being regulated or changed??
>
>Has anyone ever measured the output voltage of an arc welder with a 
>multimeter??
>(I am looking for 130-170 VAC output to my large transformer bank)
>
>I have a series of 3 (4500 VAC 450 mA) photocopier transformers, and I 
>really don't want to destroy them!!
>
>_
>
>
>
>
Depending upon the brand name of the welder ...  they range from 18V to 
40 V ( for a normal AC volt "stick welder" )   if you come across a DC 
volt welder, it can go as high as 60 VDC ....
but the amperage range will normally be bit lower than an AC machine...