[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: SRSG motor power



on that fateful day 7/29/00 4:33 PM, Tesla list uttered:

> Hey Gomez, how's things?

Cramped, but at least I now have a 2 car garage with ample power to work in,
as opposed to the previous one car with no power!

I am sorry I probably won't see your coil at the SRL show in Phoenix, unless
I can figure out a miracle.  As luck would have it, I'm part of a team
competing in the 2nd Annual Colorado Pumpkin Launch on the same day.

Don't know if you plan to attend Burning Man again, but I won't be there
either.

OK, back to business:
> One important point to remember about wind loading on rotating
> armatures is that the required power increases with the *cube*
> of the speed.

It is fortunate then, that I'm planing to run at 1800 rpm rather than 3600!

> My "guess" on your application would be about 1 to 1.5 HP at
> 3600 RPM... perhaps 10% to 20% less with good shrouding.

I've already got the rotor and stators built, and I don't see an easy way to
add shrouding after the fact.  But it may be unnecessary.
 
> I'm not sure what starting torque you should expect, as I ramp
> both of my RSG's in a controlled current fashion.

I may add a soft-start motor controller, if it seems like the motor needs
it.

> But typically 
> for a motor starting something like a pump, the start currents
> can be 5 to 10 times the running current, for several seconds.

Certainly, the locked rotor current is typically 600% of full load motor
current.

- Gomez / Bill / Arkoff

........................................................................
this message was made possible by: Bill Lemieux, Gomez A.D.D.ams, Arkoff
Kapacitor, The Mad Scientists Club, The Denver Area Science Fiction
Association, The National Security Agency, The Defense Advanced Research