Hi Chris, Did you apply the PFC caps at the input of the variac or the input of the MOT (between variac and MOT)? Steve ----- Original Message ----- From: "Chris Reeland" <chrisreeland@xxxxxxxxx> To: "Tesla Coil Mailing List" <tesla@xxxxxxxxxx> Sent: Saturday, March 17, 2018 11:55:58 PM Subject: Re: [TCML] VTTC MOT question Hi Steve, Um, yes I did start to have problems blowing or tripping the circuit breaker, after 3 times, had to quit and correct this. It was impossible to fine tune further. Realized I have now run into a poor power factor problem at the increased power level now. I will give some more details later on what I did for this to correct this. So currently I have added about 224uF in PF caps. Amp draw is now at the current state of tuning, going from 10 amps to 16 amps pulsing. Much better now! Can actually do tuning changes now no problem. So if we can eventually find out why your coil is not drawing more amps, you do need more to get the extra spark length, you may run into this also. I think you said you are currently at about 15 amps, of course no power factor correction. I have not done anything Sat on the coil. I worked very early that day. Was tired after and need to get other things done. But I can now try some things tomorrow (Sunday). I hope to give some more details and pictures. Also want to say, sounds like the better filament transformer change with meter and small variac is worth the effort and time. Besides no more surge problem of course, benefit of being able to manually regulate voltage is a big plus. I have some line voltage drop from the heavy draw of the coil running, pulls down filament some. Most tube spec sheets want you to hold unavoidable fluctuations to a minimum. Typically .3-.4 + or - max. Going low is worse. You will see where to set it on the plus side so it does not fall to low. Me when under coil running, I like to keep at +.2 for a slight safety margin for other possible load conditions. Chris Sent from my LG V20 On Sat, Mar 17, 2018, 9:44 AM Steve White <steve.white1@xxxxxxxxx> wrote: > Hi Chris, > > Wow! 23 amps at 140 volts. That is 3.2 KW. I am surprised that your 20 amp > circuit breaker doesn't blow. I guess the slow-blow action of the breaker > prevents this especially since you are pulsing. > > I think my next step will be to replace my home-made filament transformer > (rewound MOT) with a commercial filament transformer, which I now have, and > a small variac and voltmeter for filament voltage adjustment. It won't make > my sparks any longer but it will be much more efficient. My MOT-based > filament transformer draws about 750 watts! It gets quite warm even with a > cooling fan. I measured the commercial filament transformer under load and > it only draws about 120 watts and stays completely cool. > > Steve > > ----- Original Message ----- > From: "Chris Reeland" <chrisreeland@xxxxxxxxx> > To: "Tesla Coil Mailing List" <tesla@xxxxxxxxxx> > Sent: Friday, March 16, 2018 3:30:07 PM > Subject: Re: [TCML] VTTC MOT question > > Hi Steve, > > Yes, I am back to my bigger copper tube toroid again. I have said in the > past recently that I always find myself going larger especially if pulsing. > I tried 4 other smaller sizes working back up to this. I have several more > going bigger, but of course they get too physically big for the size of > this coil, and then I would run into frequency problems again, which I want > to also say if you are considering larger, you may want to figure out if > you are going to have a possible frequency problem of pulling it too low. > This is why I rewound my secondary for a higher starting frequency. I have > alot more "headroom" to try various changes. > > Yeah, having the feedback above a fairly tall primary can have some > problems. I have mentioned this also in the past. You got lucky you caught > is soon enough and have taken corrective action, I have seen variations of > what you said you did to prevent this. > > Me, I have stopped a while ago of the "traditional" above the primary. I > always put it below now. Me, I feel (and some may disagree with me, which > is ok) that even though in theory, it is only supposed to be affected by > the primary, it seems to be affected by the higher voltage built up on the > secondary on the upper end, which happens when you have a taller primary. > If a short traditional primary, it is ok above. > > At the bottom below the primary, you are of course located at the bottom of > the secondary, which is mostly current of course, and also has the benefit > of eliminating high voltage short arcs between the feedback and secondary. > I would also say this is much healthier for the grid wire of the tube to > eliminate this from happening. > > I will have more details on this later, but I "was" peaking during the > pulses about 23+ amps at "140" 100% variac input. > > I have not yet done any changes yet last night or today yet. Kind of taking > it easy...was tired from work. Going to mess around a bit later I think. > > I should be able to give more details and comments and pictures this > weekend sometime. > > Chris > > Sent from my LG V20 > _______________________________________________ > Tesla mailing list > Tesla@xxxxxxxxxxxxxxxxxx > https://www.pupman.com/mailman/listinfo/tesla > _______________________________________________ > Tesla mailing list > Tesla@xxxxxxxxxxxxxxxxxx > https://www.pupman.com/mailman/listinfo/tesla > _______________________________________________ Tesla mailing list Tesla@xxxxxxxxxxxxxxxxxx https://www.pupman.com/mailman/listinfo/tesla _______________________________________________ Tesla mailing list Tesla@xxxxxxxxxxxxxxxxxx https://www.pupman.com/mailman/listinfo/tesla