[Home][2018 Index]
I would love to see your transformer :) On Fri, Jun 29, 2018, 3:08 PM Jan Ohlsson <jan@xxxxxxxx> wrote: > HI, i am new on this list and in the early stages of designing a big coil. > A few years ago I built a medium size coil, but want to go bigger now. I > have access to at least 40 A at 400 V. Pigs are hard to come by in my > country, so I am in the final stages of fabricating my own, 55 kg UI core, > isolated with paper and in a tank under transformer oil, in the old > fashioned way. It should be capable of delivering up to 16 kVA > intermittently at 13 kV,I think. > > But now I would like to test a few ideas in this forum, before I commit. > Please correct me if they seem crazy! > > 1. The ballast should have a low flux in the core at max current, > otherwise the current limitation will be unstable due to the unlinearity of > the iron cores permeability. I am thinking of a UI core weighing 110 kg > with a good sized air gap, would that be excessive? I am planning on > several taps to be able to change the current from 10 to 40 A. > 2. The SRSG should have a high rotational speed for good quenching, I > am planning 3000 rpm and 400 mm diameter, 4 electrodes. > 3. The secondary should be wound on a tube with very low losses, I am > thinking of polyethylene, and varnished as well with low loss material, > epoxy resin. Nothing lossy inside the coil form, low dielectric loss is > very important. > 4. Secondary with large diameter, 315 mm, and not to long, 900 mm. Cu > wire 1,2 mm, low losses are more important then many turns. > 5. Very large thoroid, minor diameter 300 mm, major 1,5 m. > 6. A small thoroid under the big, to be able to raise the main > thoroid and still avoid downwards strikes. > 7. No possibility for a normal earth, the site is a big underground > bomb shelter with a very well reinforced concrete floor. I plan on using > several sheet metal plates on the floor to get a counterpoise type ground > by coupling capacitively with the metal sheets to the rebar system in the > concrete floor. The floor is very big, 1800 square meters, so it is a big > electrical mass with more or less conductive rebar. > 8. An isolating plastic sheet above the primary, to avoid strikes to > the primary. > 9. MMC capacitor bank, probably up to 200 nF, will have to be tested. > What do you think? Please feel free to critizise! > > Jan, Stockholm, Sweden > _______________________________________________ > Tesla mailing list > Tesla@xxxxxxxxxxxxxxxxxx > https://www.pupman.com/mailman/listinfo/tesla > _______________________________________________ Tesla mailing list Tesla@xxxxxxxxxxxxxxxxxx https://www.pupman.com/mailman/listinfo/tesla