[Home][2015 Index] Re: [TCML] NTC Thermistor surge suppression [Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TCML] NTC Thermistor surge suppression



Is this to code?

If there is an electrical fire, will your insurance company honor your claim
if they find any non-code items in your breaker panel.

I would do an extension cord with a box with the thermistor wired into it.

Dave

> -----Original Message-----
> From: Tesla [mailto:tesla-bounces@xxxxxxxxxx] On Behalf Of 
> David Rieben
> Sent: Sunday, January 11, 2015 11:44
> To: Tesla Coil Mailing List; Gary Lau
> Subject: [TCML] NTC Thermistor surge suppression
> 
> Hi Gary,
> 
> Just wanted to thank you for providing me the eBay link to 
> those 1 ohm, 30 amp surge suppression thermistors. I actually 
> opened my breaker box and installed one in series with the 20 
> amp breaker that feeds my outlet that I run my variacs off 
> of, making sure to provided clearance of the thermistor body 
> from any wiring in the breaker box to allow for the surface 
> heating of the thermistor to ~200 - 220C. Virtually 
> eliminates breaker tripping with variac power ups.
> 
> Thanks again,
> David
> _______________________________________________
> Tesla mailing list
> Tesla@xxxxxxxxxx
> http://www.pupman.com/mailman/listinfo/tesla

_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxx