[Home][2015 Index] [TCML] 1kw TC Best Secondary winding Design [Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[TCML] 1kw TC Best Secondary winding Design



Hi all,
Here my constraints: 10kv-100mA NST, 45nF tank capacitor and for secondary winding a pvc pipe with 200mmx900mm available 

I'm choosign between the following winding alternatives:

1- 1267 turns of wire diameter 0.71mm in order to have 900mm fitted for a total lenght = 795m  This gives considering lambda\4 resonance a frequency of 94khz and therefore 10 turns on primary inductor given the 45nF tank capacitor

2- 900 turns of wire diameter 1mm in order to have 900mm fitted for a total lenght = 565m  This gives considering lambda\4 resonance a frequency of 132khz and therefore 7.5 turns on primary inductor given the 45nF tank capacitor

What will be the best option in order to have longer streamers ?

Regards
Pier Aisa