[TCML] Pole Pig Question
They should say 14.4kV on the nameplate.
If the transformer has 7.2kV on the nameplate, its just that - 7.2kV. 7.2kV is another common primary voltage for these transformers.
You would probably want a 14.4kV/240V 5kVA or 10kVA unit. The 3kVA units are "small and cute" but harder to find.
Dan
-----Original Message-----
From: tesla-bounces@xxxxxxxxxx [mailto:tesla-bounces@xxxxxxxxxx] On Behalf Of Miles Mauldin
Sent: Thursday, July 25, 2013 7:03 AM
To: Tesla Coil Mailing List
Subject: EXTERNAL: [TCML] Pole Pig Question
Hi all,
I am in the market for a pole pig, and my first choice is a dual horn, HV 14400, LV 120/240. I se several different voltage combinations and am wondering what are the differences. My biggest question is why some of the 7200 HV units don't list 14400 as the total HV? If this information is in the archives please direct to its location.
7970/13800Y
7200/12470Y
Continue to enjoy all the expert posters and information provided.
Thanks!
Miles Mauldin
Sent from a little device with a tiny keyboard. _______________________________________________