[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [TCML] ANOTHER ONE DOWN, ANOTHER 37667 BITES THE DUST
Ye I've heard that a series/parallel combo works well. In fact used 2 in
series on my 4" 15 kV, 60 MA NST driven coil when I got the 37667's to test
them out. Worked great for the time I used them. However even if I went this
route with the 4800 watt, 6" coil I'd need to purchase 4 more. They now seem
to cost $125 each, so $500 plus the 4 @ $100 I have, ouch! A new commercial
pulse cap is in reach at this price range.
----- Original Message -----
From: "Yurtle Turtle" <yurtle_t@xxxxxxxxx>
To: "Tesla Coil Mailing List" <tesla@xxxxxxxxxx>
Sent: Sunday, May 13, 2012 4:35 AM
Subject: Re: [TCML] ANOTHER ONE DOWN, ANOTHER 37667 BITES THE DUST
I have used 10 in series/parallel for over a decade in 25 kVA use on a 10"
coil and they are still fine. I bought them in at least four different
"buys", so who knows the abuse they suffered before me, but they have
performed admirably, as long as you use two in series.
Adam
________________________________
From: MICHAEL HARDY <mhardy4@xxxxxxxxx>
To: Tesla Coil Mailing List <tesla@xxxxxxxxxx>
Sent: Saturday, May 12, 2012 11:15 PM
Subject: [TCML] ANOTHER ONE DOWN, ANOTHER 37667 BITES THE DUST
When I first decided to build a pig powered coil (2004 ), I searched for
pulse caps on the internet, and of course the infamous 37667's were
everywhere. Bought 5 at $100 each. Then found out they weren't very good for
TC's. I've since been running 3 TC rated Maxwell 0.2uF, 20 kV caps in
series, for 0.066uF @ 60kV. This on a 14.4 kV Pt powered 6" coil system
running around 4800 watts with no problem. I have recently completed a 15"
coil running at about 15 kW. I used 2 banks (including the one above) in
parallel for 0.14 uF at 60 kV. I still am running the smaller coil
routinely. Changing out one bank is a pain, so decided to try a pair of
37667's in parallel (0.06 uF @ 35kV). Ran good with only slight warmth to
cases of caps. Short 30 sec runs with 3 minute pauses. After a half hour I
saw steam from the cap bank. Checked, and one of them had split open. DON'T
BUY 37667 MAXWELL'S FOR TC USE!
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla