For the cable I use to tap into the primary, I use a "Litz-oid" arraignment
of 10 parallel lengths of 16-gauge stranded wire, "jacketed" with two
concentric split loom lengths of tubing. The result is a very flexible,
very slinky cable, with decent air-gap insulation.
Before installing the split loom, the tap cable and the copper ground ribbon
from the secondary would mutually light-up with corona, if they were within
a few inches proximity. Now, no such discharge is visible.
On Sun, Oct 31, 2010 at 12:48 PM, Gary Lau <glau1024@xxxxxxxxx> wrote:
> It really depends upon how much current is being pushed through the
> primary. On any NST-based coil, I doubt that you'd notice any performance
> difference between using reasonable lengths of common #14 copper wire and a
> copper ribbon. I think most of us tend to err on the heavy-overkill side,
> just because it looks cooler and won't hurt. The heavy wire option would
> probably being a lot tidier and one could argue less subject to corona.
>
> Regards, Gary Lau
> MA, USA
>
> On Fri, Oct 29, 2010 at 10:01 PM, Derek Esq. <a_key_move@xxxxxxxxx> wrote:
>
> > While browsing tc pages today, I noticed one of the pages had made an NST
> > based rotary spark gap tc and had used 1" wide copper foil to connect up
> the
> > primary tank connections. Does anyone have any thoughts (or personal
> > experiences) on whether copper foil is a good choice for primary
> connections
> > as opposed to heavy wire?
> >
> > Derek
> >
> >
> >
> > _______________________________________________
> > Tesla mailing list
> > Tesla@xxxxxxxxxx
> > http://www.pupman.com/mailman/listinfo/tesla
> >
> _______________________________________________
> Tesla mailing list
> Tesla@xxxxxxxxxx
> http://www.pupman.com/mailman/listinfo/tesla
>
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla