[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TCML] VA formula



Dan,

A reasonable approximation for common laminated silicon steel cores is obtained from the following formulas:

Core cross section area (sq in) = 0.16*(SQRT(VA))

or

VA Rating = ((Core Cross section area (sq in))/0.16)2

I have a .PDF spreadsheet with a number of typical values precalculated that I can send you if you want.

Lemmee know.

Dave

On 12/1/2010 6:26 PM, Dan Casaregola wrote:
I have a MMot,(read Monster Microwave Transformer) which I want to estimate the VA rating of, and I lost my notes re volt-ampere calculation using the core area squared.  This beast weighs 25 pounds, and is very well constructed.  No welds, all 1/4 20 hardware, and 1/8 inch steel mounting brackets.  Ideal for re-winding for heavy duty inductor or high current low voltage supply.  Would appreciate the formula.  Thank you. Dan
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla