Re: [TCML] fused Variac
In a message dated 1/16/09 12:13:14 P.M. Eastern Standard Time,
sparks@xxxxxxxxxxxxxx writes:
>As long as the voltage between turns is less than the contact potential,
>relatively little short circuit current will flow between turns when the
>brush bridges two turns of the winding. For this reason, most variable
>transformers tend to have windings with between 1.0 - 1.6 volts per
>turn.
Thanks, Ralph!
I've always wondered how the "shorted turn" problem was resolved in
Variacs.
-Phil LaBudde
Center for the Advanced Study of Ballistic Improbabilities