I have a 3 kV 1100 mA plate xmfr.
I also have a 14.4 kV, 10 kVA pole xmfr. Sec can be unwound to 4-5 kV
range. I remove the core/coil assembly and drop them into
a 18 x 18 square x 19" high steel tank with phenolic lid. You set sec
current with a series power reactor.
In a tank, with oil, it won't even get warm at 800 mA current draw.
Dr. Resonance
On Sat, Oct 4, 2008 at 8:15 PM, David Rieben <drieben@xxxxxxxxxxx> wrote:
Hi all,
I have been running my VTTC on 2 seriesed ouput MOTs and
am finding that the MOTs can get smoking hot and start to
stink during operation. I was wondering if anyone might have
a plate transformer rated in the 4 to 5 kV @ 600 to 800 mA
range that they would be willing to sell or trade for? Decent
plate transformers with voltage and current ratings in this
neighborhood seem hard to locate on ebay these days.
Peter Dahl made ones show up some but are quite pricey.
Thanks,
David