[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [TCML] Are safety gaps necessary? TerryFilter MOVs
I use 9 MOVs in each leg with 12/60s. No nst failures, but I also use air
core chokes on the other end of the filter.
Dr. Resonance
On Fri, Jun 20, 2008 at 10:40 AM, b alex pettit jr <a_pettit_jr@xxxxxxxxx>
wrote:
> On a related topic,
> How may MOVs are required for safe operation in the
> Terry Filter ?
>
> I have 8 per leg for the 12KV/60ma - just used the
> full set of MOVs provided in the kit, maybe too many ?
>
> Since they are rated at 1800v, 6000/1800 = 3.33
> per side, but seems as if most use many more than that ... ??
>
> Whats the consensus ?
>
> Thanks,
> Alex P
> _______________________________________________
> Tesla mailing list
> Tesla@xxxxxxxxxxxxxx
> http://www.pupman.com/mailman/listinfo/tesla
>
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla