Yes, I have a detailed drawing of a simple hyperbaric spark gap. Set gap at
200 mils (0.2") Conact me off list and I will email it to you.
With cap value of .04 uF or less, a single gap with 3/4 copper pipe works
very well. In the range of .05 to .07 uF pri cap, I use two hyperbarics
connected in series, each set at 100 mils. Above .07 uF it's best to run a
rotary spark gap.