Matt,
I had a similar problem a couple of years ago when trying to figure out
the windings of a high current transformer from a band saw blade
welder. I got readings that were all over the map, and often
inconsistent from one application of the test leads to the next.
I solved the problem by applying a 1K ohm power resistor across the
meter terminals. It seems that the high impedance digital meter was
sensing all kinds of transients off the line and giving false readings.
HTH,
Dave