[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: coil AGW, diameter, H/W (fwd)
---------- Forwarded message ----------
Date: Thu, 23 Aug 2007 23:11:09 -0500
From: resonance <resonance@xxxxxxxxxxxx>
To: Tesla list <tesla@xxxxxxxxxx>
Subject: Re: coil AGW, diameter, H/W (fwd)
Use 4.5:1 H/D ratio.
Use 1,200 turns on sec coil.
With a fixed dia, multiply x 4.5 to get the correct winding length.
Divide this length, in inches, by 1,200 turns --- this gives the correct
wire OD.
Look up the wire OD (use twin coated hi-temp wire) to determine the exact
wire guage.
For large coils, greater than 18 inch dia., go to 1,000 turns on the sec.
Use same procedure but divide winding length by 1,000.
Dr. Resonance
Resonance Research Corp.
www.resonanceresearch.com
----- Original Message -----
From: "Tesla list" <tesla@xxxxxxxxxx>
To: <tesla@xxxxxxxxxx>
Sent: Thursday, August 23, 2007 5:39 PM
Subject: coil AGW, diameter, H/W (fwd)
---------- Forwarded message ----------
Date: Thu, 23 Aug 2007 17:28:25 -0400
From: Scott Bogard <teslas-intern@xxxxxxxxxxx>
To: tesla@xxxxxxxxxx
Subject: coil AGW, diameter, H/W
Hey guys,
Does anybody out there have a good table of approximations, for
recommended wire gauge, coil diameter, and H/W ratio (example 3-in diameter,
28AWG, 5/1 H/W), from small sizes to large (like 3-in to 18-in). Just
sometihg I want to tuck away for future reference, thanks.
Scott Bogard.
_________________________________________________________________
See what you’re getting into…before you go there
http://newlivehotmail.com/?ocid=TXT_TAGHM_migration_HM_viral_preview_0507