[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Homemade Voltage Divider



Original poster: DRIEBEN@xxxxxxxxxxxxxxx

Hi Jim,

I'm pretty sure that R. Hull had the measurement
of a known fraction of HVAC when suggesting the use
of an NST to measure HV, as the 15kv/120v ratio can
easily be multiplied by the output measurement of
the reversed NST. However, I am trying to measure
high voltage DC since I'm trying to guage the ap-
plied voltage to the terminal of a huge capacitor
bank that I'm trying to charge. The reverse NST
measurement method that you propose would only
give resaonbly accurate measurement data for high
voltage AC.

David Rieben

----- Original Message -----
From: Tesla list <tesla@xxxxxxxxxx>
Date: Friday, January 27, 2006 2:45 pm
Subject: Re: Homemade Voltage Divider

> Original poster: "James Zimmerschied" <zimtesla@xxxxxxx>
>
> I am pondering a way to reliably measure 10 KVDC
> across the terminals of (2) 100 µFd energy dis-
> charge caps Original poster: "David Rieben"
>
> David
> Richard Hull showed the use of a NST is reverse
> to measure high voltages. This might be bulky but reliable.
> Jim Zimmerschied
>
>