Hi Terry,
I still think it is best to connect the NST case, your filter, safety
gap, strike rail, and secondary base to RF ground. The variac case and
EMI filter should be connected to mains safety ground. RF on the NST
case will be common mode on the line input and the EMI filter should have
a common mode choke (or two) in it. Personally, I dont want to take any
chance of a discharge resulting in transient current traveling down (or
up) the mains safety ground. This could be catastrophic to any
electronics plugged into the mains, whether turned on or off. Grounding
the coil system to mains safety ground, I believe, should only be
considered when the coil is operated inside where earth ground is not
easily available. For this case, the coil should be used with a
counterpoise, the power kept low, and great care be taken as to what the
streamers can strike.
Gerry
Original poster: Terry Fritz <teslalist@xxxxxxxxxxxxxxxxxxxxxxx>
At 04:02 PM 5/13/2005, you wrote:
In the Terry Filter he shows one side be grounded to RF (spark gap
side) and the other side of the filter be tied to the NST
case. Wouldn't this cause major RF on the NST case and maybe inducing
into house lines?
Interesting thought... I was thinking the NST case might be hit by
streamers in which case it would be best to have it tied to the RF
ground. "Maybe" there are situations where the case would be best tied
to the AC. But I normally just use the AC ground for safety since it is
terrible and conducting RF.
All my coils have MOVs and dual-stage line filters on the AC line too
:-) So maybe if you are worried, you would want to do that as
well. That stuff can be far back at say the AC power outlet. Mine are
inside the variac controller.
Cheers,
Terry