Small DC DC Conveter (SMPS) Design Help
Original poster: "Adam Horden" <adamhorden-at-acidtech-dot-net>
Hi All,
I took on the headache of building a full bridge and gate driver for a
CM600HA igbt brick full bridge. The bricks are the same the ones on Steve
Conners OLTC.
I have done the design of the gate drivers and everything works very nicely
just awaiting the pcbs from the pcb house now.
I need 4 isolated supplies (small step-down transformer and no good here
due to the winding inter capacitance and using 4 transformers 4 lots of
fuses 4 regulator stages seems a bit long winded)
So I came up with this idea.
40V supply (LV transformer full wave rectified and smoothed) > pwm osc
40Khz > mosfet driver stage > full bridge IRFP460 > transformer > 4 x
secondary 45V 1A
Everything up to the transformer is pretty standard.
There is a block diagram here http://www.acidtech-dot-net/ah-dmdrv-isolated.html
The problem is the design for the transformer. I know the turns ratio
formula and used it for standard mains transformers I have wound in the
past but can I apply this standard set of formulas here?
Would any one talk me through the design stage of the transformer or know a
book / website that can help?
Would I need an air gap to store the core saturating?
Thanks,