[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: 0.25 MFD 30 kV capacitor on eBay for TC use.



Original poster: "Mike" <mike.marcum@xxxxxxxxxxxx>

Nothing else setup another acct and relist again and again (with an increasing # after the username). I do this to sell DVD's and hard drives full of mp3's and divx files pretty often (on my 8th "disposable" acct in 6 months). I'd like to know their explanation of why you can't sell a cap, even tho pole pigs are listed and they are just as deadly in the hands of the ignorant. Anyway, with filter caps like yours the internal construction won't take too many bangs. Usually the foil/dielectric rolls are connected with a thin strip of foil that literally blows apart like a fuse if the cap is shorted over and over or it rips from the roll from magnetic forces. Also, if it's paper dielectric (or something that's rf lossy) it will heat up rather quickly, sometimes to the point of blowing up ( I think I'll remember not to use 5 kvar pfc caps again).

Mike
----- Original Message ----- From: "Tesla list" <tesla@xxxxxxxxxx>
To: <tesla@xxxxxxxxxx>
Sent: Wednesday, December 15, 2004 1:31 PM
Subject: Re: 0.25 MFD 30 kV capacitor on eBay for TC use.


Original poster: gary350@xxxxxxxxxxxxx
Ebay cancelled the auction again.  This time they suspended account.

What is the deal with this capacitor?  Why won't it last long?

Gary Weaver





-----Original Message-----
From: Tesla list <tesla@xxxxxxxxxx>
Sent: Dec 13, 2004 10:21 AM
To: tesla@xxxxxxxxxx
Subject: 0.25 MFD  30 kV capacitor on eBay for TC use.

Original poster: "Dr. Resonance" <resonance@xxxxxxxxxx>


Gary:

Please note the 0.25 MFD cap you have listed on eBay for TC use will not
last long.  I ran this part number past CI via email and they said:

Capacitor Industries, formerly Chicago Condensor Corp., quotes:

This capacitor is a DC-only capacitor to be used for blocking and coupling.
It is not to be used with AC voltages and certainly not to be used on pulse
applications. 95% Reversals at 500 Hz. will cause immediate failure.

Dr. Resonance

Resonance Research Corporation
E11870 Shadylane Rd.
Baraboo   WI   53913