[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: Filament help!
Original poster: sparks-at-spectrotek-dot-com
Be aware that most computer power supplies will shut down is the load
current exceeds the limit of the output. A large transmitting tube will
represent a load resistance close to a short circuit at cold start. You
may have to include a starting resistance in series with the power
supply and the tube to get the supply to start properly. You'll have to
bypass the resistor after the tube filament warms up.
73,
Ralph W5JGV - WC2XSR/13