[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: blowing fuses: troubles with a new system



Original poster: "Gerry Reynolds by way of Terry Fritz <teslalist-at-qwest-dot-net>" <gerryreynolds-at-earthlink-dot-net>

Has anyone experimented with an optical position sensor with a feedback
controller for the SRSP.
One would probably need a light pipe to get the sensor info to the
controller.

Gerry Reynolds
Ft Collins, CO USA


----- Original Message -----
From: "Tesla list" <tesla-at-pupman-dot-com>
To: <tesla-at-pupman-dot-com>
Sent: Friday, June 27, 2003 7:11 AM
Subject: RE: blowing fuses: troubles with a new system


 > Original poster: "Dave Kyle by way of Terry Fritz <teslalist-at-qwest-dot-net>"
<dave-at-kyleusa-dot-com>
 >
 > I experienced exactly the same symptoms in a similar sized coil and it
 > turned out my SRSG was way out of phase. My John Freau phase controller
did
 > not have sufficient range to correct for this. Only after a manual
 > adjustment to my SRSG was I able to dial things in and the massive over
 > current issue disappeared.
 >
 > =========================================
 > Dave Kyle
 > Austin, TX USA
 > Email: dave-at-kyleusa-dot-com
 >
 >
 >
 > Steve Ward.
 >
 >