[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: Mutual Inductance & K Factor
Original poster: "John H. Couture by way of Terry Fritz <twftesla-at-qwest-dot-net>" <couturejh-at-mgte-dot-com>
Bart -
Just finished checking the K factors for Kurt Schraner's BW coil of
11/24/01.
Pos = Secondary above Primary in inches.
Mark = Mark Rzeszotarski's MandKver31 program. Thank you Mark.
Pos Mark Java JHCTES
(Acmi?)
0 .1609 .1552 .137
1 .1458 .1459 .127
2 .1314 .1370 .118
3 .1182 .1287 .111
4 .1061 .1207 .103
5 .0954 .1132 .097
6 .0858 .1060 .091
This is a large secondary coil 15.8" dia x 70" long. It is interesting that
the program outputs come closer together as the coil is raised and the K
Factors become smaller. As I said all the program outputs will be equal at K
= zero. We must be doing something right. (:})
The data is entered in Java with password "Kurt1".
I couldn't find if Kurt made any K Factor test using the mutual inductance
test or the frequency test.
John Couture
-------------------------------------------