Re: Mondo Power Transformers For Sale:



Original poster: "Erik Schulz by way of Terry Fritz <twftesla-at-qwest-dot-net>" <gradient-at-mail.utexas.edu>

Jack,
    You can run all three primaries in parallel if you make the center one
opposite in polarity to the outside two.  You can do the same with the
secondary windings also.  So at 120 in you would get (360/440)*9= 7.36 kv
out.  Sounds good to me.  I wonder how the insulation looks?  Maybe we could
run two of these in series for 14.72 kv.

Erik Schulz
www.teslacoil.info

snip

>I am told they
>are configured for 440 in 3 phase and 9kv out at
>around an amp and a half. My thought: Parallel two of
>the primary windings in phase, magnetically additive,
>and drive them with 220, and then series connect two
>of the hv windings.