[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Calculation of PFC Capacitors using LTR Capacitor



Original poster: "teri mckenney by way of Terry Fritz <twftesla-at-qwest-dot-net>" <mck-at-ezy-dot-net>

Hey Dan,
Personally, I think you're putting the cart in front of the horse. You
should worry about PFC after you have sparks.I still think you might be a
turn or so short on the primary???
Billy


----- Original Message -----
From: "Tesla list" <tesla-at-pupman-dot-com>
To: <tesla-at-pupman-dot-com>
Sent: Thursday, August 01, 2002 7:16 PM
Subject: Calculation of PFC Capacitors using LTR Capacitor


> Original poster: "Mccauley, Daniel H by way of Terry Fritz
<twftesla-at-qwest-dot-net>" <daniel.h.mccauley-at-lmco-dot-com>
>
>
>
> Here is my current design:
> 15kV / 60mA NST
> Tank Capacitor - 0.0275uF
> using SRSG
>
> If I use WINTESLA, the PFC Capacitors should be approximately 165uF
assuming
> a tank capacitance of 0.0106uF.
>
> However, when using my LTR capacitance value of 0.0275uF, how does this
> affect this calculation.
>
> I guess in a properly built / properly tuned SRSG, then the system should
> work as if the NST is still charging up a
> 0.0106uF???
>
> What are your thoughts.
>
> Thanks again.
>
> Dan
>
>
>
>