Hi Malcolm,

Tesla list wrote:

> Original poster: "Malcolm Watts by way of Terry Fritz
<twftesla-at-uswest-dot-net>" <m.j.watts-at-massey.ac.nz>
>
> Hi Bart,
>         There is no question that the variation can go way beyond
> 20%. If the toroid is small enough relative to the resonator, the
> change can approach 100% - i.e. it might as well not be there at all.
> Pointless for operation but does make a point of its own.
>
> Regards,
> malcolm
>

Yes, I fully agree that 100% is possible or near possible at least. I
didn't post it, but I did test a
small toroid (almost a corona ring = 4.25" x 16.25"). This measured a 68%
error in Ctop. So yes, I
confirmed that for myself. Also, Fr change was 20.5%. Note, the Fr change
is greater than compared to the
two larger toroids. Why = Proximity? Yes, but due to what? Induction?

Take care,
Bart A.