Re: SV: NST resonance, also NST Failures
Original poster: "Terry Fritz" <twftesla-at-uswest-dot-net>
Hi Jon,
Wow! That is interesting! That is just the kind of odd arc path "I" would
expect from RF hitting a big winding like that. Thanks for passing this
info on.
Cheers,
Terry
At 10:02 PM 2/10/2001 -0500, you wrote:
snip...>
>On the topic of NST failures related to HV RF, I have performed a post
>mortem on
>two such about ten years ago. In both cases I found the failure mode to be
>inter
>layer arcing along the outside edge of one secondary coil. Both arcs were from
>one end of the outer layer to a point about one third in towards the bobbin,
>burning the edges of the paper insulation between these points and the
>insulation off the wire. The wire was also found to be burned open at the
inner
>most point of the failure site. At the time of failure, these had been in use
>without safety gaps or other filtration.
>
>For the record...
>--
>Jon G. Tebbs
><jgtebbs-at-eos-dot-net>
>