Re: Re: transformer question



Are you sure? With both the secondaries AND the primaries in series? I've
often wondered about that configuration and have never seen any thought
or questions about it before.

Just to be sure you (and Reinhard!!) get it, I am talking about LEAVING
THE CASES UNGROUNDED. Just from a hypothetical, and not neccesarily
practical, point of view. If the primaries are in series, then there
would be no extra stress on the insulation for the seriesed secondaries,
as the total volatge would be equal to that of one original transformer.
...and the current would be doubled, would it not?

-Grayson

On Wed, 25 Aug 1999 11:38:13 -0600 Tesla List <tesla-at-pupman-dot-com> writes:
> Original Poster: "The Flavored Coffee Guy" <elgersmad-at-msn-dot-com> 
> 
> 
> 
>     No, it would double the voltage and run at the same current as 
> rated for
> a single transformer.  Be careful that they are the same make and 
> model, and
> are classified as isolation transformers.  Outside of the normal 
> safeties,
> this is one to add to the list, because out phase they are a short.
> 
> 
> James.
> 
> -----Original Message-----
> From: Tesla List <tesla-at-pupman-dot-com>
> To: tesla-at-pupman-dot-com <tesla-at-pupman-dot-com>
> Date: Tuesday, August 24, 1999 7:46 AM
> Subject: Re: transformer question
> 
> 
> >Original Poster: Grayson B Dietrich <electrofire-at-juno-dot-com>
> >
> >Yes, it is very possible to parallel them, for 9KV 60ma. Hook both 
> the
> >secondaries in parallel, amd both the primaries, as well. This 
> means that
> >each terminal of one NST willl be connected to one of the others'.
> >Otherwise, I think that one could also wire both the primaries and
> >secondaries series, for the same effect. That way, each transformer 
> would
> >be running at half voltage, but would it still double the amperage? 
> I
> >dunno, so stick with paralleling them.
> >
> >
> >-Grayson Dietrich
> >"The Electrophile"
> >www.electrophile.8m-dot-com
> >
> >
> >On Sun, 22 Aug 1999 15:15:28 -0600 Tesla List <tesla-at-pupman-dot-com> 
> writes:
> >> Original Poster: Matus <matus-at-snet-dot-net>
> >>
> >> I have two 9 kilovolt neon sign transformers both rated at 30 ma, 
> is
> >> it
> >> possible to hook these up in parrallel to attain twice the 
> amperage
> >> at 9
> >> kv?  Is this a simple question of how they are hooked up or is it
> >> either
> >> not possible at all or too complicated.
> >>
> >> Thanks in advance
> >>
> >> Matus
> >>
> >>
> >
> >___________________________________________________________________
> >Get the Internet just the way you want it.
> >Free software, free e-mail, and free Internet access for a month!
> >Try Juno Web: http://dl.www.juno-dot-com/dynoget/tagj.
> >
> >
> 
> 
> 
> 