[Prev][Next][Index][Thread]
Neon Phasing?
----------
From: Keith Maddox [SMTP:kmaddox-at-burgoyne-dot-com]
Sent: Tuesday, June 16, 1998 9:52 PM
To: Tesla List
Subject: Re: Neon Phasing?
Tesla List wrote:
> ----------
> From: Stefan Bishay [SMTP:stefan00-at-gte-dot-net]
> Sent: Monday, June 15, 1998 10:43 PM
> To: tesla-at-pupman-dot-com
> Subject: Neon Phasing?
>
> I know that NSTs can be hooked up in parallel for more current, but can I
> take four NSTs and put the secondaries in parallel and the primaries in
> series-parallel so that the bank will draw 240v off the line?
>
>
> Stefan Bishay
> KC7SJC
> Seattle, WA
> ICQ 2141646
> "Hell, we all die in the end"
> -Jello Biafra
Yes, but remember your phasing since the two primaries should be 180 degrees
out of phase. You MUST phase them properly on the primary side since each
NST has two secondaries with one terminal grounded each to the core and
ground lug. Put a clip on ammeter on the Nutral line and watch what it
does. If it draws any current at all, you've done something wrong.
-Keith