> I have two H&R 5Kv xfmrs being used in series for my primary. I
> have not turned my coil on yet but they work great (cap testing)
> without tapping the connection between the two secondaries to ground.
> Some have said they have connected this to ground and others said they
> have not. I was wondering what advantage , if any, comes from grounding
> this center connection.
Advantage #1: If you ground the "center tap" then the voltage between the
winding and the core cannot go above the output voltage, and hence, not
destroy the insulation.