[Prev][Next][Index][Thread]
Re: New Coil Measurements
A bit more on this....
> Fp Cp Lp Ecp k Spark Vo(35k/") Vo(lumped)
>
> 84.8k 50n 70.5u 2.7J 0.23 12" 420kV 429kV
> 68.8k 100n 57.4u 6J 0.17 19" 665kV 640kV
> 66.5k 200n 28.7u 8.1J 0.18 22" 770kV 743kV
> 71.7k 200n 25uH 11J 0.15 25" 875kV 866kV
>
> Notes: - interesting correspondence between spark length based on
> 35kV/" and theoretical lumped calc. This is almost certainly too high
> as no losses in prim are taken into account. My guess is that 40kV/"
Should be 30kV/inch, not 40.
Primary k's are particularly interesting. The 25uH primary has an
inside diameter of 5.5" and outer diameter of 14" (cf resonator
diameter of 16.8"). The resonator was sitting atop a piece of
plexiglass directly on top of this coil. The 28 - 29uH primary was
this coil + the outer turn of a second spiral sitting an inch below
it. Worth noting that a decent k can be achieved with a very compact
primary system. This bodes well for bottling the system up as a
single unit.
Malcolm