Jim,

I saw your post last week on this and I didn't see anyone respond.  I have a
saucer shapped primary 14 turns of 3/8 copper tubing wound at 30 degrees.  I
used the formula for calculating a flat spiral primary and came within 5%.  I
calculated 86uh and measured 82uh.

Ed Sonderman