[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Re-entrant portion of the sphere (VDG) (fwd)
- To: <hvlist@xxxxxxxxxx>
- Subject: Re: Re-entrant portion of the sphere (VDG) (fwd)
- From: Steven Roys <sroys@xxxxxxxx>
- Date: Mon, 13 Oct 2003 22:01:02 -0600 (MDT)
---------- Forwarded message ----------
Date: Mon, 13 Oct 2003 08:06:51 -0700
From: Daniel Reinders <danreind@xxxxxxx>
To: High Voltage list <hvlist@xxxxxxxxxx>
Subject: Re: Re-entrant portion of the sphere (VDG) (fwd)
I found layering on a thick bead of silicone helped enormously in keeping
the corona at the column entry point down. Looked awful though.
Dan
----- Original Message -----
From: "High Voltage list" <hvlist@xxxxxxxxxx>
To: <hvlist@xxxxxxxxxx>
Sent: Monday, October 13, 2003 5:20 AM
Subject: Re-entrant portion of the sphere (VDG) (fwd)
> Original poster: Steven Roys <sroys@xxxxxxxx>
>
>
>
> ---------- Forwarded message ----------
> Date: Mon, 13 Oct 2003 06:55:12 EDT
> From: Lyonelb@xxxxxxx
> To: hvlist@xxxxxxxxxx
> Subject: Re-entrant portion of the sphere (VDG)
>
> A large diameter sphere with a small re-entrant radius is a must.The
point
> of column entry is the electrically weakest region on the terminal. This
can
> be offset to a considerable extent by arranging the electrode with a
> re-entrant portion into which the column fits. This results in a
diminution of the
> field intensity at this point and thus in a shielding of this electrically
weak
> region.
> However to make this re-entrant portion is not easy. Any idea ?
>
> Lyonel Baum
>
>
>