[Prev][Next][Index][Thread]
Re: Spark Gap Question
In a message dated 5/14/00 8:31:19 PM Pacific Daylight Time, tesla-at-pupman-dot-com
writes:
<< Original Poster: "A W" <fateagk-at-home-dot-com>
I am building a RQ gap and I am in need of information. I am confused
about the spacing between each gap. I am using seven 3/4 inch pipe
couplers for six gaps in a 4" pvc pipe. My power source is a 12/30 NST
and using WinTesla, it says I need .2381" between each gap. I havnt seen
anybody that says they need that much of a gap. On the websites I have
seen, people say they have a total gap of that much with an individual
gap size of like .03". What is correct. I am trying to follow specs that
coilers are using on their coils that are proven to work. I am also
trying to use wintesla as a reference. Can someone please help?
Thanks,
Andrew
>>
Andrew,
You want 6 gaps of .025" to .030" each. I used brass bolts to mount my
copper pipe sections. Leave these long enough so you can make connections to
any of the individual pipes. This allows you to select more or less total
gap spacing, which you will find handy somewhere along the line.
Ed Sonderman