[Home][2022 Index]
Hi Mike, I would have thought some of the firing positions will coincide with near zero mains volts, so very little power. I know with my 200bps gap, depending on phasing just one set fire giving 100bps effective. The nonfiring set are cold. At the best position I get full/even 200bps. Colin. Get Outlook for Android<https://aka.ms/AAb9ysg> ________________________________ From: mike tucknott <michaeltucknott@xxxxxxxxxxxxxx> Sent: Wednesday, June 22, 2022 10:15:55 AM To: TCML <tcml@xxxxxxxxxxxxxxx> Subject: [TCML] Sync RSG Hi All An i missing something here, one set of flying electrodes on my sync rotary spark gap are very cool if not cold to the touch after a run. All the rest show signs of use and heat. Spec - 3000RPM motor so 50RPS with 8 flying electrodes sould give me 400BPS the supply feq in the UK is 50Hz I`m using a phase controller with +/- 30deg of movment. Thoughts.... Cheers Mike Tucknott _______________________________________________ Tesla mailing list -- tcml@xxxxxxxxxxxxxxx To unsubscribe send an email to tcml-leave@xxxxxxxxxxxxxxx