[Home][2020 Index] Re: [TCML] Variac problem. [Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TCML] Variac problem.



Shaun....have had the same problem with 4 different units.   The brushes
corrode into place and allow arcing to the windings and the burn a turn.
You have to gently tap back and forth to get it loose......take you
time......it will come free.

When you are loose take the sides and lightly sand the corrosion  off so
the brush so it slides freely in the slot.  Might have to sand the slot
also.  A nail file comes in handy.  No oil!   Can use graphite powder for
lube.

Bud


On Fri, Dec 4, 2020, 6:26 AM shaun <snoggle@xxxxxxxxxxxxxx> wrote:

>
>
> I have a powerstat 1156b 45 amp variac. Does anyone know the mechanics of
> changing the brush assembly.? I have removed the two screws but seems to be
> froze in place. Not knowing how it's mounted I don't want to pry and break
> it. I have included a couple of pictures.
>
>
>
>
> https://drive.google.com/drive/folders/1afwuQQNYbbad2pJKcihc3bZHvYg67o3-?usp
> =sharing
> <https://drive.google.com/drive/folders/1afwuQQNYbbad2pJKcihc3bZHvYg67o3-?usp=sharing>
>
>
>
>
>
>
>
>                                           Thanks Shaun Noggle
>
> _______________________________________________
> Tesla mailing list
> Tesla@xxxxxxxxxxxxxxxxxx
> https://www.pupman.com/mailman/listinfo/tesla
>
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxxxxxx