Hi Albert,

Using a common RF ground should not be a problem. If the two coils are in close proximity, you will get significant E-field coupling, and some H-field coupling as well, even if the RF grounds are independent. A common RF ground will work best when the coils are being used 180 degrees out of phase (in bipolar mode).

Bert
--
Bert Hickman
Stoneridge Engineering LLC
Woodridge, Illinois, USA

Albert via Tesla wrote:
Hi,
When running two SSTC's side by side can they share the same RF ground wire to earth rods,
or share same earth rods with seperate wires to the rods?

I am concerned of possible RF feedback from one SSTC into the other.